رکورد قبلیرکورد بعدی

" Transocular Doppler and optic nerve sheath diameter monitoring to detect intracranial hypertension "


center : Isfahan University of Medical Sciences
Document Type : Latin Dissertation
Language of Document : English
Record Number : 107538
Doc. No : T17099
Call number : WL203,S558t,2016
Main Entry : Shirazinejad, Somayeh
Title & Author : Transocular Doppler and optic nerve sheath diameter monitoring to detect intracranial hypertension\ Somayeh Shirazinejad
College : Schools, Medical
Date : , 2016
Degree : Speciality
field of study : Radiology
Page No : 5p.: diag, tab
Note : This is a research dissertation with project ID: 392067
: سمیه شیرازی نژاد
Abstract : BACKGROUND:Increases in intracranial pressure (ICP) require a rapid recognition to allow for adequate treatments. The aim of this study was to determine whether transocular Doppler and optic nerve sheath diameter (ONSD) monitoring could reliably identify increases in ICP.MATERIALS AND METHODS:This is a cross-sectional case-control study, which was carried out on 2013. Subjects were chosen from patients who admitted to the neurology and neurosurgery departments and the intensive care unit of Alzahra Hospital (Isfahan, Iran). To measure the ICP, the authors used ultrasound to measure the diameter of the optic nerve sheath and transocular Doppler (TOD) to measure blood flew velocity in ophthalmic artery (OA) and ophthalmic vein (OV) in both groups.RESULTS:The mean of ONSD was 4.8 mm (SD 0.77) in patients with raised ICP and 3.2 mm (SD 0.3) in healthy volunteers which was significant (P < 0.001). The mean (SD) of TOD parameters were also significantly more in OA and OV of patients with raised ICP.CONCLUSION:Ultrasound methods has been proposed as an alternative safe technique for invasive ICP measuring methods.
Descriptor : Intracranial Hypertension
: Ultrasonography, Doppler, Transcranial
: Optic Nerve
Added Entry : Karami, Mehdi, Thesis advisor
: Shaygannejad, Vahid, Consulting advisor
Translated Title Supplied by Cataloguer : ترانس اکلار داپلر و عصب بینایی نظارت قطر غلاف برای تشخیص فشار خون داخل جمجمه
کپی لینک

پیشنهاد خرید
پیوستها
عنوان :
نام فایل :
نوع عام محتوا :
نوع ماده :
فرمت :
سایز :
عرض :
طول :
Transocular Doppler and optic nerve sheath diameter monit...
somayeh Shirazinejad F.pdf
پایان نامه لاتین
متن
application/pdf
675.34 KB
85
85
موجودی
کتابخانه مؤیدالاطباء
نمایش کامل جزئیات | عدم نمایش جزئیات
جزئیاتمحل نگهداریشماره ثبتشناسه بازیابیجلدوضعيتتاريخ برگشت
2 - کتابخانه مؤیدالاطباء10507موجود‭‬
نظرسنجی