Title & Author : Ultrasonography predictive factors of response to local steroid injection in patients with carpal tunnel \ Hadiseh Ramezanian
College : Schools, Medical
Date : , 2016
Degree : Speciality
field of study : Physical Medicinen and Rehabilitation
Page No : 19 P.: tab
Note : This is a research dissertation with project ID: 394227
: حدیثه رمضانیان
Abstract : Objectives: To determine the predictive value of ultrasonography for results of local steroid injection in patients with carpal tunnel syndrome.Methods: This prospective cohort study was conducted during a 1-year period in outpatient clinics of rehabilitation and physical medicine including 35 patients with moderate and severe carpal tunnel syndrome who receive ultrasonography-guided local steroid injection. The Boston self-assessment questionnaire and electrodiagnosis parameters were recorded at baseline, 1 month and 3 months after therapy. We also recorded the baseline ultrasonography parameters to determine the predictors of outcome. Results: The sensory severity score and functional status scale along with electrodiagnosis parameters decreased significantly at 1 month (p<0.001) and remained unchanged after 3 months. Volar bulging was negatively associated with sensory nerve action potential latency (r=−0.392; p=0.020). Cross-sectional area of maximal swelling (r=0.409; p=0.015) Cross-sectional area at 2-cm of maximal swelling (r=0.563; p<0.001), Cross-sectional area at 12-cm of maximal swelling (r=0.521; p=0.001) correlated positively with compound muscle action potential amplitude while maximal swelling/12-cm maximal swelling ratio (r=−0.439; p=0.008) and maximal swelling/ 2-cm maximal swelling ratio (r=−0.342; p=0.045) correlated negatively. Cross-sectional area at 12-cm of maximal swelling also correlated positively with compound muscle action potential amplitude nerve conduction velocity (r=0.436; p=0.010).Conclusion: Volar bulging, cross-sectional area of maximal swelling, cross-sectional area of maximal swelling at 2-cm and cross-sectional area of maximal swelling at 12-cm are among the ultrasonographic predictors of response to local steroid injection in patients with carpal tunnel syndrome.
Descriptor : Carpal Tunnel Syndrome
: Steroids
: Ultrasonography
: Forecasting
Added Entry : Dehghan, Farnaz, Thesis advisor
: Haghighat, Shila, Thesis advisor
عنوان :
نام فایل :
نوع عام محتوا :
نوع ماده :
فرمت :
سایز :
عرض :
طول :
Ultrasonography predictive factors of response to local s...
ramezanian hadisseha.pdf
پایان نامه لاتین
متن
application/force-download
48 KB
85
85